P-Xylene-Recovery by Adsorption
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
United Nations Industrial Development Organization
DOI
Abstract
The UOP Parex process was the first commercial process. It is a continuous
process using a fixed bed of adsorbent. All process streams are in the
liquid phase at constant temperature in the bed. Feed is introduced and
p-xylene is se 1ect i ve 1y adsorbed. The adsorbed p-xylene is recovered from
the pores of the adsorbent by displacement with another liquid hydrocarbon.
The stream leaves the adsorbent bed with both the p-xylene product and the
rejected raffinate streams The desorbent is recovered from these two
streams by fractionation and is recycled to the adsorbent bed. A rotary
valve is employed in the process to stimulate countercurrent flow of solid
and liquid without actual movement of the solid adsorbent.